Used Waters SYNAPT HDMS Q-TOF Mass Spectrometer For Sale

Asking Price
$94,000
Stock:
Only 1 Available on the Marketplace!
Seller:
Member ID 41989 - avatar

Fatih B.

Member since: September 2011

More listings by this seller

Make an Offer Ask the Seller a Question
Name:
Waters SYNAPT HDMS Q-TOF Mass Spectrometer
Listing Reference:
618455
Price:
$94,000
Location:
CA, USA
Age:
Unknown
Description:

The Waters SYNAPT HDMS Q-TOF Mass Spectrometer ( QTOF LCMSMS MSD G1 High Definition Mass Spectrometry Quadruple Time of Flight ) is designed for leading researchers working at the limits of conventional mass spectrometry capabilities who need to further characterize and define their samples, Waters SYNAPT HDMS System offers unique, enabling functionality. Waters SYNAPT HDMS System enables the analysis of samples differentiated by size and shape, as well as mass, to deliver increased specificity and sample definition beyond that achievable by conventional mass spectrometers. System Includes:
Computer & Software
Edwards XDS 35i Roughing Pump
Waters Reagent Manager
Waters Switching Valve
Optional:
ACQUITY UPLC System
The SYNAPT HDMS System can operator in two modes: a) TOF mode b) Mobility-TOF mode TOF Mass Resolution in Positive Ion a) V Mode: 10,000 measured on the (M + 6H)^6+ isotope cluster from bovine insulin (m/z 956) b) W Mode: 17,500 measured on the (M + 6H)^6+ isotope cluster from bovine insulin (m/s 956) TOF Mass Resolution in Negative Ion a) V Mode: 10,000 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431) b) W Mode: 17,500 measured on the (M - 4H)^4- isotope cluster from bovine insulin (m/z 1431) Positive Ion MS Sensitivity a) V Mode: The peak at m/z 556 from a solution of 50 pg/µL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, infused at a flow rate of 5 µL/min, will have an intensity of greater than 1,700 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin) and the mass range will be set to 1,000 Da. b) EDC: The peak at m/z 556 from a solution of 10 pg/µL leucine enkephalin in 50/50 acetonitrile/water + 0.1% formic acid, infused at a flow rate of 5 µL/min, will have an intensity of greater than 2,000 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), with sensitivity set to a maximum at 556 Da. Negative Ion MS Sensitivity: V Mode: The peak at m/z 503 from a solution of 500 pg/µL raffinose in 70/30 acetonitrile/water (no additives), infused at a flow rate of 5 µL/min, will have an intensity of greater than 1,800 counts per second. The instrument will be tuned to 10,000 resolution (as demonstrated on bovine insulin), and the mass range will be set to 1,000 Da. Positivt Ion MS/MS Sensitivity V Mode: Using a [Glu]-Fibrinopeptide B solution of 100 fmol/µL, at a flow rate of 5 µL/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the most intense y sequence ion from the MS/MS spectrum of the doubly charged precursor ion (785.8 Da) will be greater than 130 counts per second. This will correspond to a signal to noise ratio of greater than 50:1 (after a 3x9 smooth) on the most intense y sequence ion, for a 1 second scan. The instrument mass range will be set to 2,000 Da. Negative Ion MS/MS Sensitivity V Mode: Using a solution of 500 pg/µL raffinose in 70/30 acetonitrile/water, at a flow rate of 5 µL/min and with the instrument tuned for 10,000 resolution (as demonstrated on bovine insulin), the intensity of the fragment ion at 179.1 Da in the MS/MS spectrum of the precursor ion at 503.2 Da will be greater than 130 counts per second. The instrument mass range will be set to 1,000 Da. Mass Scale Calibration Accuracy The mass measurement accuracy of the instrument in V-mode, using an internal lockmass, is such that the RMS error between the measured and the accepted masses of peaks which have sufficient intensity, and are free from interference from other masses, will be less than 2 ppm over the range of 150-900 Da. Mass Measurement Accuracy The mass measurement accuracy of the instrument, in W-mode, will be better than 2 ppm RMS, based on 10 consecutive repeat measurements of the [M + Na]^+ ion of raffinose (m/z 527.1588), using the [M + H]^+ ion of leucine enkephalic (556.2771) as the LockSpray lockmass. Analyte lockmass peaks must have sufficient intensity and be free of interference from other masses. Mass Range: The TOF mass range is 20 - 100,000 Da in V-mode, and 20 - 26,500 Da in W-mode. The quadrupole mass range in non-resolving mode is 20 - 16,000 Da for a 4,000 Da quadrupole, and 20 - 32,000 Da for an 8,000 Da quadrupole.

Used equipment can sell very quickly. Contact the seller asap to discuss this Waters SYNAPT HDMS Q-TOF Mass Spectrometer.

Make an Offer Ask the Seller a Question
Asking Price
$94,000
Stock:
Only 1 Available on the Marketplace!
Seller:
Member ID 41989 - avatar

Fatih B.

Member since: September 2011

More listings by this seller

Make an Offer Ask the Seller a Question
Make the Seller an Offer

Make the Seller an Offer

* required field

$ (USD)

Sending an offer to the seller does not constitute a legally binding agreement to purchase the equipment. However, please only make an offer if you are seriously interested.

Your offer will be emailed to the seller immediately. We will email you their reply as soon as we receive it.

Ask the Seller a Question

Ask the Seller a Question

* required field

Your question will be sent to the seller immediately and we will email you as soon as they reply.