Description
Hazardous Waste Incineration Plant – Inciner8 I8-1000
Manufacturer: Inciner8 International Ltd., United Kingdom
Condition: Installed, fully operational, complete documentation and CE certification
The Inciner8 I8-1000 is a high-performance system for thermal treatment of hazardous and industrial waste, featuring fully automatic loading, dual-chamber combustion, and an integrated flue-gas cleaning system.
Designed for ease of operation, robust construction, and long service life, the unit ensures full compliance with EU Directive 2000/76/EC and the European Industrial Emissions Directive (IED).
The system guarantees complete oxidation of waste under controlled temperature and residence time, resulting in non-hazardous ash and emissions meeting EU regulatory limits.
• Type: Dual-chamber incinerator with secondary afterburner
• Model: Inciner8 I8-1000 C/W Eco Flam Burners
• Feeding capacity: up to 330 kg per batch (automatically adjusted to waste type)
• Combustion temperatures: Primary 800–1100 °C | Secondary ≥ 850 °C (2 s residence time)
• Loading system: Hydraulic RAM feeder with automatic door and safety interlocks
• Auxiliary fuel: Low-NOx diesel burners (two-stage surface-stabilized combustion)
• Operation mode: Underpressure – 2 mbar (ID fan with frequency control)
• Heat recovery: Air-cooled heat exchanger for waste-heat utilization (up to 400 °C)
Flue-Gas Cleaning System (Pollution Control System – PCS):
Three-stage treatment:
1. Heat exchanger – rapid cooling of flue gases below 425 °C
2. Powder dosing unit – hydrated lime/limestone injection for neutralization of acid gases (HCl, SO₂, HF)
3. Ceramic candle filter – final filtration of particulates, heavy metals, and residual compounds
Key features:
• Ceramic filter candles with automatic reverse-pulse cleaning
• Particulate emissions (PM₁₀ / PM₂.₅) < 1 mg/Nm³
• Integrated system preventing de novo dioxin formation by maintaining temperature > 800 °C and removing chlorine compounds
Continuous Emission Monitoring System (CEMS):
• Measured parameters: O₂, CO, CO₂, NO, NO₂, HCl, HF, TOC, particulates, humidity, pressure, temperature
• Ranges: in accordance with EN 14181 (O₂ 0–25%, CO 0–4000 ppm, etc.)
• Data management: USB / Internet output, software package included
Certification & Compliance:
• CE Declarations of Conformity for the complete system and subsystems (autoloader, ID fan, PCS)
• Manufacturer ISO quality certification
• Complies with EU Directives: 2006/42/EC (Machinery), 2014/35/EU (Low Voltage), 2014/30/EU (EMC)
• Emission testing: QUAL 1 Test Report No. 05/24-01-2019 – confirmed compliance with 2000/76/EC
Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase