Hitachi MRP 7000
Systems which first popularized the very concept of Open MR Because of its dependability, the MRP-7000 remains popular more than a decade after the first U.S. system was shipped. In fact, an overwhelming percentage of the MRP systems sold in the U.S. are still performing clinical scans today. This, combined with the tendency of all Hitachi MR systems to maintain high resale values, has made this system one of the most sought-after scanners on the used equipment market.
Hitachi MRP 7000 gives you the following benefits:
Gantry:Large rectangular opening and short gantry length
Table:Speed power-driven longitudinal movement, Power driven vertical movement down to 17" for patient convenience, Power-driven lateral movement for easy positioning and optimal anatomical localization, Table weight limit of 500lbs.
Gradient System:8mT/m Gradient Amplitude, >700msec slew rate.
Computer and Reconstruction System:32 bit multitasking CPU, Dedicated array processors for image reconstruction and processing, High-resolution display (512 X 512), DICOM 3.0 compliance (optional).
Magnet:.3 Tesla, Permanent, Vertical Orientation, Self Shielded, 8.0'(horizontal) x6.8' (vertical) – 5 Gauss fringe field
The Hitachi MRP 7000 provides you with with the following Specification:
CLINICAL APPLICATIONWhole body
CONFIGURATIONVertical Orientation Field
SURFACE COILSDualQuad T/R Body Coil, MA Head, MA C-Spine, MA Shoulder, MA Wrist, MA CTL Spine, MA Knee, MA TMJ, MA Flex Body (3 sizes), Neck, small and large Extremity, PVA (WIP), Breast (WIP), Neurovascular (WIP), Cardiac (WIP) and MA Foot//Ankle (WIP)
SPECTROSCOPYNo
SYNCHRONIZATIONCardiac gating, ECG/peripheral, respiratory gating (2 modes)
PULSE SEQUENCESSE, GE, GR, IR, FIR, STIR, ss-FSE, FSE, DE-FSE/FIR, FLAIR, ss/ms-EPI, ss/ms EPI- DWI, SSP, MTC, SE/GE-EPI, MRCP, SARGE, RSSG, TRSG, BASG, Angiography: CE, PC, 2D/3D TOF
IMAGING MODESSingle, multislice, volume study
MAGNET TYPEPermanent, self shielded
FIELD STRENGTH0.3 T
STRENGTH8 mT/m
5-GAUSS FRINGE FIELDhorizontal 2.5 m x 2.1 m vertical
SHIMMINGAuto shimming, 3-axis/patient and active shimming
This equipment is located in US
Manufacturer | Hitachi |
Model | MRP 7000 |
Year | - |
Country | USA |
Condition | Good |
Main category | Lab, Medical and Bioscience |
Subcategory | Hospital Equipment |
ID | P90528222 |
Client type | Machinery dealer |
On Kitmondo since | 2010 |
Number of listings | 0 |
Country | USA |
Last activity | July 18, 2023 |