Waters ACQUITY TQD LCMS MS Price drop


Availability: listing already sold

Listing description

Waters Acquity TQD LC/MS/MS System

NOTICE: This is a lease return; it has been under service contract and it is in excellent condition.

The Waters ACQUITY TQD features the highest levels of tandem quadrupole MS selectivity, robustness, speed, and accuracy for quantitative analysis. The ACQUITY TQD provides superlative analytical detection limits, resolution and sample throughput for bioanalysis, ADME screening, food safety, environmental monitoring, clinical and forensic applications, and more.

Features:

Dual Orthogonal API source maximizes longevity, protects it from dirty samples and allows easy cleaning without breaking vacuum
Automated system checks and simplified user interface for ease-of-use
Optimized MS/MS detection for demanding quantitative applications
Rapid data acquisition rates for the best in accuracy and reproducibility of chromatographic peak area measurement
ZSpray atmospheric pressure ionization interface
Industry-leading multimode capability in a single run
Smallest MS/MS footprint
Operates at the highest data acquisition rates (utilizing T-Wave collision cell, multi-mode ionization, and rapid polarity switching technologies)

Waters ACQUITY TQ Detector

Waters ACQUITY TQ Detector The Waters® ACQUITY® TQ Detector is an advanced bench top tandem quadrupole mass detector designed for ultra high performance LC/MS/MS applications. With a wide range of ionization options including Atmospheric Pressure Photo Ionization (APPI) and the Atmospheric Solids Analysis Probe (ASAP), the TQ Detector is ideally suited for a wide range of qualitative and quantitative applications. The system includes IntelliStart™ Technology, for automated system optimization and status monitoring, ensuring that the highest quality data is routinely available to users of all levels.

SYSTEM HARDWARE SPECIFICATIONS

API sources and ionization modes    

High performance ZSpray™ dual-orthogonal API sources:

ESI (standard)
Multimode source – ESI/APCI/ESCi® (standard)
Dedicated APCI (optional)
Dual-mode Atmospheric Pressure Photo Ionization (APPI)/APCI source (optional)
Atmospheric Solids Analysis Probe (ASAP) (optional)
Vacuum isolation valve Tool free access to customer
Serviceable elements Plug and play probes De-clustering
cone gas Software control of gas flows and heating elements
Ion source transfer optics - High efficiency hexapole ion guide

Mass analyzer - Two high resolution quadrupole analyzers (MS1/MS2), plus prefilters to maximize resolution and transmission while preventing contamination of the main analyzers.

Collision cell- T-Wave™1 enabled for optimal MS/MS performance at high data acquisition rates Software programmable gas control.

Detector -Low noise, off axis, long life photomultiplier detector Digital dynamic range up to 4 x 106.

Vacuum system- Single, split-flow air-cooled vacuum turbomolecular pump evacuating the source and analyzer. One rotary backing pump.

Dimensions-  

Width: 34.5 cm (13.8 in.)
Height: 53.3 cm (20.8 in.)
Depth: 88.5 cm (34.6 in.)
Regulatory approvals/marks-CE, CB, NRTL (CAN/US), RCM

SYSTEM SOFTWARE SPECIFICATIONS

Software-Systems supported on MassLynx® 4.1 or Empower® 2 software (and later versions).

IntelliStart Technology-System parameter checks and alerts Integrated sample/calibrant delivery system plus programmable divert valve Automated mass calibration Automated sample tuning Automated MRM and SIR method development LC/MS System Check – automated on-column performance test.

Quantification methods database*Quanpedia™ – a database for storing and sharing user defined LC/MRM acquisition methods and associated processing methods for the targeted quantification of named compounds. Database entries for a number of applications are also provided.  Quanpedia is an optional software item included with the purchase of the TargetLynx Application Manager.

MRM acquisition rate assignment*Dwell time, inter-channel delay time, and inter-scan delay times for individual channels in a multiple MRM experiment can be automatically assigned (using the Auto-Dwell feature) to ensure that the optimal number of MRM data points per chromatographic peak are acquired. The Auto-Dwell feature can dynamically optimize MRM cycle times to accommodate retention time windows that either partially or completely overlap. This greatly simplifies MRM method creation, irrespective of the number of compounds in a single assay, while at the same time ensuring the very best quantitative performance for every experiment.

MRM acquisition window assignment*Multiple MRM experiments can be scheduled (manually or automatically using the Quanpedia database) using retention time windows to optimize the cycle time for each MRM channel monitored. If required, MRM retention time windows can overlap partially or completely. This ensures that MRM data acquisition rates will be optimal for the quantification of all analytes in a given assay.

PERFORMANCE SPECIFICATIONS

Acquisition modes

Full scan MS
Product ion scan
Precursor ion scan
Constant neutral loss
Selected Ion Recording (SIR)
Multiple Reaction Monitoring (MRM)
Survey scan modes* Full scan MS triggered product ion scan

Mass range- 2 to 2048 m/z

Scan speed-Up to 10,000 Da/s

Examples of achievable acquisition rates- 

10 scans per second (m/z 100 to 1000)
20 scans per second (m/z 50 to 500)
Mass stability-Mass drift is <0.1 Da over a 24 hour period

Linearity of response-The linearity of response relative to sample concentration for a specified compound is five orders of magnitude from the limit of detection

Polarity switching time- 20 ms to switch between positive and negative ion modes

ESCi mode switching time-20 ms to switch between ESI and APCI

MRM acquisition rate** Minimum dwell time of 3 ms per MRM channel

Inter-channel cross talk-The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 10 ms and an inter-channel delay time of 10 ms, will be less than 0.02%.

Number of MRM channels***Up to 16,384 MRM channels (512 functions, 32 channels per function) can be monitored in a single acquisition; up to 1024 MRM channels when operating in GLP/secure mode (32 functions, 32 channels per function).

Mass resolution-Automatically adjusted (IntelliStart) to desired resolution; The valley between the 2034.63 Da and 2035.63 Da peaks is <12% of the average height of the two peaks.

MRM sensitivity (ESI+)- A 1 pg on-column injection of reserpine will give a chromatographic signal-to-noise greater than 2,000:1 (Gradient separation, LC mobile phase flow rate of 0.8 mL/min, MRM transition m/z 609 > 195).

MRM sensitivity (ESI-)-  

A five pg loop injection of chloramphenicol, with a mobile phase flow rate of 200 µL/min will give a chromatographic signal-to-noise for the transition 321 > 152 m/z greater    than 180:1.

MRM sensitivity (APCI+)- A 100 pg loop injection of 17-a-hydroxyprogesterone, with a mobile phase flow rate of 1000 µL/min will give a chromatographic signal-to-noise for the transition 331 > 109 m/z > 150:1.

*Feature is only available on systems controlled by MassLynx 4.1 SCN#714 or later.

**3 ms dwell is only available with systems controlled by MassLynx 4.1 SCN#714 or later. Systems controlled by Empower 2 have a minimum of 5 ms dwell. Both systems have 5 ms inter-channel delay.

***512 function operation is only available with systems controlled by MassLynx 4.1 SCN#714 or later. Empower 2 controlled systems monitor a maximum of 1024 MRM or SIR channels (32 functions, 32 channels per function)

System Includes:

TRAY
MS
COLUMN OVEN
AUTO SAMPLER
PUMP
PDA DETECTOR
TRANSE
VACUUM PUMP
COMPUTER MONITOR

This equipment is located in US


Please note that this description may have been translated automatically.

Availability: listing already sold

Listing information

Manufacturer Waters
Model ACQUITY TQD LCMS MS
Year -
Country USA USA
Condition Excellent
Main category Miscellaneous industrial equipment
Subcategory Chromatograph and spectrometer
ID P71005008

Availability: listing already sold

About the seller

Client type Machinery dealer
On Kitmondo since 2011
Number of listings 35
Country USA USA
Employees 11 - 50
Established 2007
Company description

We are dedicated to supporting researchers with high-quality, pre-owned instruments at affordable cost, along with expert service and support. While specializing in ion chromatography systems, gas… read more

We are dedicated to supporting researchers with high-quality, pre-owned instruments at affordable cost, along with expert service and support. While specializing in ion chromatography systems, gas chromatographs, liquid chromatography equipment, mass spectrometers (GCMS Systems, LCMS Systems), and microplate readers, we also offer a wide range of laboratory instruments in all other fields.

Last activity April 18, 2024