Specifications

-------------------
Length x width x height 900.0 × 2000.0 × 800.0
Weight 1160 kg
worked hours
hours under power
state as-is, where-is
At local norms ---------
status

Description

Manufacturer: Weiss

Type: SD 1400/+20 DU

Test chamber:

Material: Stainless steel

dimensions

Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm

Capacity: 1440 liters

Outer casing

Material: double-coated Zincor sheet metal

dimensions

Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm

HxWxD 2000 x 2200 x 2000 mm

Paint finish: light gray (RAL 9002)

Door, double-leaf: hinged left and right


Equipment:

Feed-through in floor and ceiling: 2 each, NW 100 mm, for inserting the pulsating tables

Feed-through in the side walls: 1 each, left, right, 100 mm

Cooling unit: air-cooled

Control: DMR digital measuring and control system

Basic control panel: integrated in the main switch panel

Interface: RS 232 C, for connection to a PC

Software: Operating software for MS-Windows


Performance data:

Temperature range without air conditioning: +20...+100 °C

Temperature stability without climate control: +0.2 ... t0.5 K (in time) depending on range, in steady state

Temperature range with climate control: 20...+95 °C

Temperature stability with climate control: +0.2 ... +0.5 K (in time) depending on range, in steady state

Dew point range: 20...+94 °C

Humidity range: 10...98 % RH

Humidity stability: +3 ... +5 % r.h. depending on range, in steady state

Temperature change rate measured in blow-out without test specimen and without load
- Cooling: 0.5 K/min. on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. on average, between +20 and +100 °C

The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage
For proper operation of the system, the ambient temperature must be between +10 and +35 °C

Connections / Other

Protection class: IP 32 for the control cabinet

Sound pressure level with free-field measurement at a distance of 1 m in front of the device: 60 dB (A)

Humidification water: fully demineralized, conductivity max. 20 pS/cm, pH value 6 - 7, automatic replenishment

Condensate drain: back pressure-free, 3/4" hose connection

Mains connection: 400 V; 3 PH+N PE; 50 Hz

Connected load: max. 10 KVA

Weight: approx. 1160 kg

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Client type Reseller
Active since 2009
Offers online 32
Last activity June 26, 2025

Description

Manufacturer: Weiss

Type: SD 1400/+20 DU

Test chamber:

Material: Stainless steel

dimensions

Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm

Capacity: 1440 liters

Outer casing

Material: double-coated Zincor sheet metal

dimensions

Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm

HxWxD 2000 x 2200 x 2000 mm

Paint finish: light gray (RAL 9002)

Door, double-leaf: hinged left and right


Equipment:

Feed-through in floor and ceiling: 2 each, NW 100 mm, for inserting the pulsating tables

Feed-through in the side walls: 1 each, left, right, 100 mm

Cooling unit: air-cooled

Control: DMR digital measuring and control system

Basic control panel: integrated in the main switch panel

Interface: RS 232 C, for connection to a PC

Software: Operating software for MS-Windows


Performance data:

Temperature range without air conditioning: +20...+100 °C

Temperature stability without climate control: +0.2 ... t0.5 K (in time) depending on range, in steady state

Temperature range with climate control: 20...+95 °C

Temperature stability with climate control: +0.2 ... +0.5 K (in time) depending on range, in steady state

Dew point range: 20...+94 °C

Humidity range: 10...98 % RH

Humidity stability: +3 ... +5 % r.h. depending on range, in steady state

Temperature change rate measured in blow-out without test specimen and without load
- Cooling: 0.5 K/min. on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. on average, between +20 and +100 °C

The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage
For proper operation of the system, the ambient temperature must be between +10 and +35 °C

Connections / Other

Protection class: IP 32 for the control cabinet

Sound pressure level with free-field measurement at a distance of 1 m in front of the device: 60 dB (A)

Humidification water: fully demineralized, conductivity max. 20 pS/cm, pH value 6 - 7, automatic replenishment

Condensate drain: back pressure-free, 3/4" hose connection

Mains connection: 400 V; 3 PH+N PE; 50 Hz

Connected load: max. 10 KVA

Weight: approx. 1160 kg

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Specifications

-------------------
Length x width x height 900.0 × 2000.0 × 800.0
Weight 1160 kg
worked hours
hours under power
state as-is, where-is
At local norms ---------
status

About this seller

Client type Reseller
Active since 2009
Offers online 32
Last activity June 26, 2025

Here is a selection of similar machines

Weiss SD 1400/+20 DU Laboratory equipment