Machinery
Choose from 20,024 used machinery listings
- Auctions
- Sell machines
- Sell complete plants
- What is Kitmondo?
- About us
- Blog
One (1) Medtronic Biphasic 3 Lead Patient Monitor and Defibrillator.
Includes accessories pictured: SPo2 sensor, 1 sterile Co2 tubing and bite block, ECG leads, Soft case, AED Cable, and 100mm recorder
Does not include: Hard paddles, Charging base
GENERAL The LIFEPAK 12 defibrillator/monitor series has five main operating modes:
Advisory Mode (SAS): Provides all features available except manual defibrillation, synchronous cardioversion and pacing.
Manual Mode: Provides normal operating capability for ALS users. Setup Mode: Allows operator to customize the device.
Service Mode: Allows operator to execute device diagnostic tests and calibrations.
Inservice Mode: Provides simulated waveforms for demonstration purposes.
DATA MANAGEMENT The device captures and stores patient data, events (including waveforms and annotations), user test results and continuous ECG waveform records in internal memory.
The user can select and print reports and transfer the stored information via an internal modem through landline or mobile phones.
Report Types: Three format types of CODE SUMMARY™ critical event record (short, medium and long)
• Initial ECG (except short format)
• Automatic capture of vital signs measurements every 5 minutes
• 3-channel or 4-channel 12-lead ECG report
• Continuous waveform records (transfer only)
• Trend Summary – includes patient information, vital signs log and vital signs graphs
• Vital Signs – includes patient information, event and vital signs log.
• Snapshot – includes patient information and 8 seconds of ECG captured at the time of transmission
Memory Capacity: Two full-capacity patient records that include: CODE SUMMARY critical event record – up to 100 single waveform events Continuous Waveform – 45-minute continuous ECG record
MONITOR
SpO2
Nellcor sensors
SpO2 Measurement Range: 50 to 100%
SpO2 Waveform: IR pleth signal
SpO2 Update Rate: as each pulse is detected
Calibration Range: 70 to 100%
SpO2 Measurement: Functional SpO2 values are displayed and stored Pulse Rate: +/- 3 pulses per minute
Dynamic signal strength bar graph
Pulse tone proportional to value of displayed oxygen saturation
EtCO2
Microstream™ technology
Measurement Range: 0 to 99mmHg
Display: CO2 waveform and EtCO2 numerics
Units: mmHg, kPa, %; user selectable Automatic ambient pressure compensation
CO2 Accuracy (>20 minutes): 0 to 38mmHg: ± 2mmHg 39 to 99mmHg: ± 5% of reading + 0.08% for every 1mmHg
Warm Up Time: 30 seconds (typical), 180 seconds max
Response Time: 2.9 seconds (includes delay time and rise time)
Respiration Rate Range: 0 to 60 breaths per minute Respiration Rate
Accuracy: 0 to 40 bpm: ± 1 bpm 41 to 60 bpm: ± 2 bpm
ADVISORY
Shock Advisory System (SAS) is an ECG analysis system that advises the operator if the algorithm detects a shockable or non-shockable ECG rhythm. SAS acquires ECG via therapy electrodes only.
Shock Ready Time: Using a fully charged battery at normal room temperature, the device is ready to shock within 20 seconds if the initial rhythm finding is “Shock Advised.”
Output Energy (Biphasic): User configurable, sequence of three sequential shock levels ranging from 200, 200 to 300, and 200 to 360 joules. * Note: ±5% accuracy applies when disposable therapy electrodes are attached. Energy output is limited to the available energy which results in delivery of 360 joules into 50 ohms.
PRINTER
Prints continuous strip of the displayed patient information
Paper Size: 50mm (2.0 in) or optional 100mm (3.9 in)
Print Speed: 25mm/Sec +/- 5% (measured in accordance with AAMI EC-11, 4.2.5.2)
Delay: 8 seconds
Autoprint: Waveform events print automatically (user configurable) Optional 50mm/sec timebase for 12-lead ECG reports
This equipment is located in US
Manufacturer | Medtronic |
Model | Lifepak 12 |
Year | - |
Country | USA |
Condition | Good |
Main category | Lab, Medical and Bioscience |
Subcategory | Hospital Equipment |
ID | P50701013 |
Client type | Machinery dealer |
On Kitmondo since | 2015 |
Number of listings | 0 |
Country | USA |
Last activity | July 1, 2015 |