Description
Equipment description
The device is used as a backup source of 1.8 MPa steam, especially in case of failure of one of the back pressure turbo generators, when there is a deficit of 1.8 MPa steam or in other special manipulations requiring the reduction station as a source of 1.8 MPa steam by direct reduction from 9.6 MPa steam.
A total of 4 of these reduction stations are used in the steam system of the Heating Plant.
Basic parameters of the equipment
Steam:
quantity before RS 100 max. 105 t h-1
pressure before RS 9,0 MPa max. 9,6 MPa
temperature before RS 515° C max. 530° C
temperature after RS 320° C max. 360° C
pressure after RS 1,8 MPa
Cooling water:
pressure before RS 3.6 - 3.8 MPa
temperature before RS 150° C
quantity before RS 14,0 max. 20,0 t h-1
Opening overpressure of safety valves: 1 pc 2,4 MPa, 1 pc 2,5 MPa.
Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase